Site Planning
Workstation Setup Guide 21
Site Planning
When preparing your site, you must consider the environmental, electrical,
and space requirements for your Avid|DS workstation, as well as any
additional equipment that you may need to purchase and its requirements.
Environmental
Requirements
The site you choose for your Avid|DS workstation should meet the following
environmental requirements:
Clean and dust free
Free from significant temperature or humidity changes
Sturdy, level, and not subject to vibration
Away from high-traffic or high-noise areas
Provides adequate space in front of and behind the workstation
components, so that you can connect cables and service your workstation.
This also provides adequate air flow for cooling.
A minimum clearance of 3 inches (7.6 cm) for the side and back panels of
the desk side base unit
A table (or other surface) that is at least 60 inches wide by 48 inches deep
(150 cm × 120 cm) for the editing workstation
Electrical
Requirements
Your site should meet the following electrical requirements:
Adequate power for each workstation component, so that extension cords
are not needed.
At least two 15-amp circuits available; one for the workstation and one for
the Avid MediaDock LVD storage(s).
Site is away from major electrical equipment, such as motors, air
conditioners, or elevators.
Site is not subject to static electrical buildup.
Uses an uninterruptible power supply (UPS) to protect your workstation
from sudden power surges or losses, and save you from the resulting loss
of work.
Plug only your Avid|DS equipment into the power strip. Do not plug
in coffee makers, radios, lights, or other such devices.